190mm Ultra Thin Ceiling Horizontal Fan Coil Unit

190mm ultra thin suspending fan coil unit

Built-in water tray, no corrosion, no deformation

EVA thermal insulation cotton to prevent condensation

DC Brushless motor


Additional information

Voltage

220V-240V

Air Flow

690m³/h-1745m³/h

Cooling Capacity

3.6KW-9.0KW

Heating Capacity

5.4KW-13.5KW

Product Video

Description

Ceiling Horizontal Fan Coil Unit Applications

With the rise of various buildings, Various decoration conditions have also become diversified, The ceiling space limits some rooms, and There are also requirements for the thickness of fan coil units. Ultra-thin horizontal fan coil unit are aimed at such customers.

  • 3 rows,  24 copper pipes
  • Only 18.8cm thick, thinner than standard fan coil units 45-100mm。
  • ABS fan, ultra-thin Ceiling horizontal concealed fan coil unit running noise is low
  • It integrates a fan coil unit and intake plenum, the default mode is with a straight intake.

Fan Coil Unit Working principle

Fan coil unit structure diagram The function of a ceiling horizontal fan coil unit is to cool or heat indoor air or outdoor mixed air through the surface cooler and then send it into the room so that the indoor air temperature can be lowered or raised to meet people’s comfort requirements. Cold (hot) medium water in the coil pipe is supplied centrally by the machine room. Product Details

  • The motor of ceiling horizontal Fan Coil Unit : Changzhou Liwen motor, thickened shock absorption on both sides and stable operation
  • Lug: Hang the whole unit
  • Fan of ceiling horizontal Fan Coil Unit : ABS fans, anti-corrosion, anti-weathering, long service life. Good airflow design, low running noise of the machine.
  • Drain pan: Contain condensed water discharged from refrigeration, and stick rubber and plastic to keep warm.
  • Ceiling Horizontal Fan Coil Unit Motor board: Galvanized steel plate with a thickness of 1.0mm, reinforced to increase the hardness of sheet metal.
  • Fan Coil Condensor: High-density hydrophilic aluminum foil of fan coils, pure copper pipeline, mechanical tube expanding process.
  • Junction box: Built-in wiring terminal, convenient wiring
  • Condensate drain pipe: DN20 outer wire
  • Inlet pipe: DN20 inner wire, enlarged copper head
  • Outlet pipe: DN20 inner wire, enlarged copper head
  • Inlet and outlet pipelines: Four-in and four-out, the designed water resistance conforms to GB/T19232, and the heat exchange efficiency is high.

Parts of fan coil units Technical Data

Type
FP68
FP102
FP170
Airflow  m³/h
690
1085
1745
Motor power  W
12
25
40+40
Quantity of Motor
1
1
2
Quantity of Fan
2
2
4
Power  W
20
37
130
Noise  dB(A)
36
47
47.5
Size   mm
910*495*200
1170*495*200
1610*495*200
Air outlet static pressure
12pa
Weight   kg
16
19.9
28.4
Length of condensor
650mm
913mm
1353mm
Width of condensor
200
Thickness of condensor
65
Copper
3 rows
Water pipe
4 in 4 out
Diameter of copper tube
φ9.52mm
Copper tube thickness
0.26mm
Aluminum foil thickness
0.105mm
Fin spacing
1.3mm
Panel material
0.8mm galvanized sheet

Drawing

Type
Total length A
Unit length B
Length of air outlet C
Lug spacing D
FP68
910mm
822mm
650mm
870mm
FP102
1170mm
1085mm
910mm
1130mm
FP170
1610mm
1525mm
1350mm
1570mm

			

Additional information

Voltage

220V-240V

Air Flow

690m³/h-1745m³/h

Cooling Capacity

3.6KW-9.0KW

Heating Capacity

5.4KW-13.5KW

Reviews

There are no reviews yet.

Be the first to review “190mm Ultra Thin Ceiling Horizontal Fan Coil Unit”

Your email address will not be published. Required fields are marked *

Ceiling Horizontal Fan Coil Unit Applications

With the rise of various buildings, Various decoration conditions have also become diversified, The ceiling space limits some rooms, and There are also requirements for the thickness of fan coil units. Ultra-thin horizontal fan coil unit are aimed at such customers.

  • 3 rows,  24 copper pipes
  • Only 18.8cm thick, thinner than standard fan coil units 45-100mm。
  • ABS fan, ultra-thin Ceiling horizontal concealed fan coil unit running noise is low
  • It integrates a fan coil unit and intake plenum, the default mode is with a straight intake.

Fan Coil Unit Working principle

Fan coil unit structure diagram The function of a ceiling horizontal fan coil unit is to cool or heat indoor air or outdoor mixed air through the surface cooler and then send it into the room so that the indoor air temperature can be lowered or raised to meet people’s comfort requirements. Cold (hot) medium water in the coil pipe is supplied centrally by the machine room. Product Details

  • The motor of ceiling horizontal Fan Coil Unit : Changzhou Liwen motor, thickened shock absorption on both sides and stable operation
  • Lug: Hang the whole unit
  • Fan of ceiling horizontal Fan Coil Unit : ABS fans, anti-corrosion, anti-weathering, long service life. Good airflow design, low running noise of the machine.
  • Drain pan: Contain condensed water discharged from refrigeration, and stick rubber and plastic to keep warm.
  • Ceiling Horizontal Fan Coil Unit Motor board: Galvanized steel plate with a thickness of 1.0mm, reinforced to increase the hardness of sheet metal.
  • Fan Coil Condensor: High-density hydrophilic aluminum foil of fan coils, pure copper pipeline, mechanical tube expanding process.
  • Junction box: Built-in wiring terminal, convenient wiring
  • Condensate drain pipe: DN20 outer wire
  • Inlet pipe: DN20 inner wire, enlarged copper head
  • Outlet pipe: DN20 inner wire, enlarged copper head
  • Inlet and outlet pipelines: Four-in and four-out, the designed water resistance conforms to GB/T19232, and the heat exchange efficiency is high.

Parts of fan coil units Technical Data

Type
FP68
FP102
FP170
Airflow  m³/h
690
1085
1745
Motor power  W
12
25
40+40
Quantity of Motor
1
1
2
Quantity of Fan
2
2
4
Power  W
20
37
130
Noise  dB(A)
36
47
47.5
Size   mm
910*495*200
1170*495*200
1610*495*200
Air outlet static pressure
12pa
Weight   kg
16
19.9
28.4
Length of condensor
650mm
913mm
1353mm
Width of condensor
200
Thickness of condensor
65
Copper
3 rows
Water pipe
4 in 4 out
Diameter of copper tube
φ9.52mm
Copper tube thickness
0.26mm
Aluminum foil thickness
0.105mm
Fin spacing
1.3mm
Panel material
0.8mm galvanized sheet

Drawing

Type
Total length A
Unit length B
Length of air outlet C
Lug spacing D
FP68
910mm
822mm
650mm
870mm
FP102
1170mm
1085mm
910mm
1130mm
FP170
1610mm
1525mm
1350mm
1570mm

		

Please enter your email to let us contact you

We will contact you within 1 working day, please pay attention to the email with the suffix “@aircolder.com”