Search
Close this search box.

High-efficiency water-cooled cassette fan coil unit air conditioning equipment is needed to dissipate high temperatures

For different modes of transport, we have different packing methods:
1. Waterproof and moisture-proof polyurethane is wrapped around the outside of the product, and then delivered by express or
air freight with plywood boxes
2. Some transportation methods may be limited, we can use 1.5cm thick honeycomb cartons with corner protection
3. If the goods are large, we also use wooden cases or pallets for LCL

The warehouse area is about 4000 square meters, the storage capacity is large, and the minimum long-term inventory is 20,000 units to ensure the
circulation of goods. “The same day orders, the same day delivery”, more efficient and smooth distribution, to achieve customer satisfaction.
We are close to the port of Tianjin, Beijing Airport and Xi ‘an Railway Station and can be reached by a variety of transportation methods:
1) Bulk orders can be shipped by sea, air and rail, and we are close to Tianjin Port, Beijing Airport and Xi ‘an Railway Station.
2) Sample orders can be shipped by express, such as DHL, FedEx, UPS, TNT or EMS.
3) Sample orders can also be delivered to the door by sea, air or train, including taxes.

Description

Water-cooled cassette fan coil unit for central air conditioner system

Water card fan coil unit for central air conditioner system

Water card fan coil unit for central air conditioner systemWater card fan coil unit for central air conditioner system

Water card fan coil unit for central air conditioner system

The low-noise three-speed capacitor motor of well-known domestic brands is adopted, with imported precision ultra-low-noise rolling bearing.

Water card fan coil unit for central air conditioner system

Three-dimensional spiral wind blade ensures wind volume and thinner shape, and irregular wind blade pitch greatly reduces operating noise.

Water card fan coil unit for central air conditioner system

 

The  pipe of water collecting head adopts forged brass structure, which is reliable and durable.

Water card fan coil unit for central air conditioner system

 

 

Circular heat exchanger design, wind uniformity, seamless copper tube and new high-efficiency corrugated double curved open window hydrophilic aluminum foil fin, optimize flow design and effectively improve heat transfer efficiency.

Water card fan coil unit for central air conditioner system

 

 

 Foam insulation, thickening foam insulation layer inside the fuselage, not easy to produce condensation beads in summer, not easy to corrode, and extend the service life.

 

Water card fan coil unit for central air conditioner system

 

4-way water-cooled cassette fan coil unit

Model and performance   FP-34 FP-51 FP-68 FP-85 FP-102 FP-136 FP-170 FP-204 FP-238
Rated air flow

m3/h

high 340 510 680 850 1020 1360 1700 2040 2380
Medium 280 390 520 640 790 1030 1290 1500 1800
low 180 260 350 430 520 690 860 1030 1200
Rated cooling capacity

W

high 1980   3680 4980 5580 7200 9900 10800 12600
Medium 1631 2279 2814 3750 4322 5534 7512 8088 9681
low 1048 1519 1894 2519 2854 5534 5008 5554 6454
Rated heat

W

high 2980 4800 5480 7200 8180 10800 14500 16200 18900
Medium 2454 3671 4191 5421 6335 8179 11005 12353 14521
low 1578 2447 2821 3600 4481 5479 7335 8482 9681
The input power W 34 50 58 72 92 126 128 152 198
The amount of water

m3/h

0.42 0.52 0.62 0.86 0.98 1.08 1.58 1.78 1.92
Water press loss

Kpa

14 14 16 18 22 25 39 44 46
Motor number 1 2 3 4  
power 220V~240/50HZ

 

1. The rated air volume refers to the outlet static pressure of 0Pa.
2. Cooling operation parameters: inlet air dry bulb temperature is 27℃, humidity temperature is      19.5℃, outlet water temperature is 7℃, return water temperature is 12℃.
3. Heating condition parameters: inlet air dry bulb temperature is 20℃, inlet water temperature      is 60℃, outlet water temperature is 50℃.

 Water card fan coil unit for central air conditioner systemWater card fan coil unit for central air conditioner system

Reviews

There are no reviews yet.

Be the first to review “High-efficiency water-cooled cassette fan coil unit air conditioning equipment is needed to dissipate high temperatures”

Your email address will not be published. Required fields are marked *

Related Product

Yesncer Fan Coil Unit Manufacturer

Search

Sign up to our newsletter

Please enter your email to let us contact you

We will contact you within 1 working day, please pay attention to the email with the suffix “@aircolder.com”

Welcome Back

Everything is where you left it.

You seem to like our product content very much.

Give us your contact information and we will send you more detailed product data and provide professional project solutions.

Which product are you interested in?

Fill out the form below to tell us what products and information you are interested in, or tell us about your project.

We will reply within 24 hours.

Registration

To reserve your ticket please fill out the registration form