Description
Application
A Ceiling cassette fan coil unit is a kind of equipment installed at the end of an air conditioner, which is widely used in our work and life. In our big family of fan coils, 4-way cassette fan coil is a very good type of fan coil. 4-way cassette fan coil unit is exquisitely structured, compact, durable, beautiful in appearance, noble and elegant, and is embedded with ultra-thin fuselage in large shopping malls and office buildings.
360-degree uniform air outlet without a crash, with water as the medium to exchange cold and hot, which fully saves energy and protects the environment. The unique adjustment switch with three gears can select different comfortableness for different people so that everyone can feel the charm of the air conditioner and enjoy the temperature.
Working principle:
The function of concealed fan coil is to cool or heat indoor air or outdoor mixed air through the surface cooler and then send it into the room so that the indoor air temperature can be lowered or raised to meet people’s comfort requirements. Cold (hot) medium water in the coil pipe is supplied centrally by the machine room.
Product Details
Equipped with a drainage pump. The advanced 4-way cassette Fan coil is equipped with a condensed water drainage pump, which is flexible in design and can easily remove condensed water。
Fan: ceiling cassette fan coil unit the three-dimensional spiral blades ensure the air volume and thinner shape, and the irregular blade pitch greatly reduces the running noise
The condenser and the round condenser increase the heat dissipation area, and the heat dissipation is more evenly combined with multiple water inlet and outlet heads, which can accelerate the heat exchange speed and improve the heat exchange efficiency.
The air inlet filter is fixed by snap, which is convenient to disassemble and clean the filter screen.
Motor, the motor is a general motor with stable performance. The installation position of the motor is increased in density and thickened in rubber to
reduce the noise and resonance generated by the motor during operation.
Technical Data OF Ceiling Cassette Fan Coil Unit
Technical Data of 2 Pipe Fan Coil Unit | ||||||||||
Model and performance | FP34 | FP51 | FP68 | FP85 | FP102 | FP136 | FP170 | FP204 | FP238 | |
Rated air flow m3/h |
high | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
Medium | 280 | 390 | 520 | 640 | 790 | 1030 | 1290 | 1500 | 1800 | |
low | 180 | 260 | 350 | 430 | 520 | 690 | 860 | 1030 | 1200 | |
Rated cooling capacity W |
high | 1980 | 2980 | 3680 | 4980 | 5580 | 7200 | 9900 | 10800 | 12600 |
Medium | 1631 | 2279 | 2814 | 3750 | 4322 | 5534 | 7512 | 8088 | 9681 | |
low | 1048 | 1519 | 1894 | 2519 | 2854 | 5534 | 5008 | 5554 | 6454 | |
Rated heating capacity W |
high | 2980 | 4800 | 5480 | 7200 | 8180 | 10800 | 14500 | 16200 | 18900 |
Medium | 2454 | 3671 | 4191 | 5421 | 6335 | 8179 | 11005 | 12353 | 14521 | |
low | 1578 | 2447 | 2821 | 3600 | 4481 | 5479 | 7335 | 8482 | 9681 | |
The input power | W | 34 | 50 | 58 | 72 | 92 | 126 | 128 | 152 | 198 |
The amount of water m3/h |
0.42 | 0.52 | 0.62 | 0.86 | 0.98 | 1.08 | 1.58 | 1.78 | 1.92 | |
Water press loss Kpa |
14 | 14 | 16 | 18 | 22 | 25 | 39 | 44 | 46 | |
Motor number | 1 | |||||||||
power | 220V~240/50HZ |
Technical Data of 4 Pipe Cassette Fan Coil Unit | ||||||||||
Model and performance | FP34 | FP51 | FP68 | FP85 | FP102 | FP136 | FP170 | FP204 | FP238 | |
Rated air flow m3/h |
high | 360 | 520 | 650 | 840 | 1000 | 1320 | 1660 | 1950 | 2090 |
Medium | 290 | 420 | 510 | 670 | 800 | 1050 | 1330 | 1560 | 1670 | |
low | 220 | 310 | 390 | 500 | 600 | 790 | 1000 | 1170 | 1250 | |
Rated cooling capacity W |
high | 1980 | 2980 | 3680 | 4980 | 5580 | 7200 | 9900 | 10800 | 12600 |
Medium | 1631 | 2279 | 2814 | 3750 | 4322 | 5534 | 7512 | 8088 | 9681 | |
low | 1048 | 1519 | 1894 | 2519 | 2854 | 5534 | 5008 | 5554 | 6454 | |
Rated heating capacity W |
high | 1950 | 3000 | 3750 | 4850 | 5750 | 7400 | 9700 | 10900 | 11850 |
Medium | 1700 | 2550 | 3200 | 4100 | 4850 | 6250 | 8200 | 9250 | 10050 | |
low | 1350 | 2000 | 2500 | 3250 | 3850 | 4950 | 6500 | 7300 | 7950 | |
The input power | W | 34 | 50 | 58 | 72 | 92 | 126 | 128 | 152 | 198 |
The amount of water m3/h |
0.42 | 0.52 | 0.62 | 0.86 | 0.98 | 1.08 | 1.58 | 1.78 | 1.92 | |
Water press loss Kpa |
14 | 14 | 16 | 18 | 22 | 25 | 39 | 44 | 46 | |
Motor number | 1 | |||||||||
power | 220V~240/50HZ |
Note:
1. The rated air volume refers to the outlet static pressure of 0Pa.
2. Cooling operation parameters: inlet air dry bulb temperature is 27℃, humidity temperature is 19.5℃, outlet water temperature is 7℃, return water temperature is 12℃.
3. Heating condition parameters: inlet air dry bulb temperature is 20℃, inlet water temperature is 60℃, outlet water temperature is 50℃.
Drawing
Reviews
There are no reviews yet.