I.Project introduction

Shenyang jianzhu university Pension Experience Testing Center was approved by Liaoning Development and Reform Commission, researched and developed by shenyang jianzhu university Pension Industry Architectural Information Research Institute, provided design guidance by shenyang jianzhu university Architectural Design and Research Institute, and built by Shenyang Fengming Construction Engineering Co., Ltd., which is a demonstration project of nearly zero energy consumption and suitable for the elderly. The building adopts the near-zero energy consumption building technology system independently researched and developed by shenyang jianzhu university, with the energy saving rate of demonstration project being over 95%, and the technical autonomy rate of the building system reaching over 90%, which indicates that the near-zero energy consumption building technology system independently researched and developed by China is maturing day by day, and also indicates that the application of local materials and technologies can fully meet the international leading passive house standards.

.Customer requirements

Heating at room temperature reaches 23 degrees in winter and cooling in summer. Comprehensive energy efficiency ratio above 2.5

Ⅲ. Design scheme

The scheme uses air source heat pump as cold and heat source, with fan coil at the cooling end and geothermal at the heating end.

Four fresh air units are arranged indoors to ensure the oxygen content of fresh air.

The minimum thermal resistance of air-conditioning duct is greater than or equal to 0.81㎡kw.

Ⅳ Indoor environment detection

  • indoor temperature In December, the indoor temperature remained at a high level of about 23℃.
  • Indoor humidity The average indoor humidity is kept at 20% in December

V. Actual use effect

Energy saving and environmental protection

Energy consumption of heating system: the total power consumption of heating system is 600.7kw/h, and the average daily power consumption is 22.25kw h/d

Comfort

Indoor temperature reaches heating standard, cooling is comfortable, fresh air system is provided, indoor oxygen content is high, and comfort is strong.

Facebook
Twitter
LinkedIn

Leave a Reply

Your email address will not be published. Required fields are marked *

Yesncer Fan Coil Unit Manufacturer

Search

Sign up to our newsletter

Please enter your email to let us contact you

We will contact you within 1 working day, please pay attention to the email with the suffix “@aircolder.com”

Welcome Back

Everything is where you left it.
Receive the latest news

You seem to like our article.

Get notified about new articles

You seem to like our product content very much.

Give us your contact information and we will send you more detailed product data and provide professional project solutions.

Which product are you interested in?

Fill out the form below to tell us what products and information you are interested in, or tell us about your project.

We will reply within 24 hours.

Registration

To reserve your ticket please fill out the registration form