1-way/2-way/8-way Cassette Fan Coil Unit

Data sheet of 1-way/2-way/8-way Cassette Fan Coil Unit

You can choose according to your needs according to these data

Previous slide
Next slide

        4-way cassette fan coil unit is one of the most popular fan coil units, because of the high efficient performence and beautiful appearance. 4 air outlets make the supply air softer and people feel more confortable.It is widely applicated in hotels, restaurants, bars, schools, offices and other commercial places.

  • Drain pump built-in or natural drainage
  • 3-speed motor is long-life,low noise and energy saving
  • Removable filter screen, easy to clean and minnannence
  • Strong and durable centrifugal fan makes quietand stable air supply
  • Polyurethan drain pan make low noise and no consensation
  • Wired control or remote control to adjust the temperature
ModelFP-34FP-51FP-68FP-85FP-102FP-136FP-170FP-204FP-238

Cooling Ca. (kw)

(Water in 7℃)

( Air inlet temperature: DB 27℃,WB19.5℃)

H1.982.983.684.985.47.29.910.812.6
M1.632.272.813.754.325.537.518.089.68
L1.041.511.892.512.855.535.005.556.45

Heating Ca. (kw)

(Water in 60℃)

( Air inlet temperature: DB 20℃)

H2.974.805.487.208.110.8014.5016.2018.90
M2.453.674.195.426.338.1711.0012.3514.52
L1.572.442.823.604.525.477.338.489.68
Air flow(m³/h)H345510690875103513751705)20452380
M2803905206407901030129015001800
L18026035043052069086010301200
Power Input(W)5050587292126128152198
Current (A)0.1510.2250.2580.320.3850.5610.5470.6770.882
Noise dB (A)373941434546474952
Static pressure (Pa)12
Power Supply220-240v/1ph/50Hz
Control wayWired or remote controller
Water flow (m³/h)0.420.520.620.860.981.081.581.781.92
Water pressure drop(kPa)141416182225394446
Water pipe for in/outZG3/4”
Installation Drawing
Installation Drawing

Hang the indoor unit as shown in the drawing:

  1. Adjust the relative position of the hook on the suspension bolts to keep the unit at the same level in all directions, otherwise it may cause water leakage, air leakage and other faults.
  2. Tighten the nuts to ensure that the four mounting hooks are in close connnection with the nuts and gaskets and there is no virtual hanging phenomenon.
  3. Ensure that the fan coil unit must not shake or be insufficiently positioned after installation.
  4. Ensure that the center of the unit is basically the same as the center of the ceiling opening after installation.
  1. Connect one end of the soft drain pipe to the water outlet of the fan coil unit and the other end to tightly connect the DN20 hard PVC pipe
  2. The drain pipe must be set downward with a slope of 1/100 or greater:
  3. An additional insulation sleeve is should be used to wrap the hard PVC pipe to prevent condensation on the surface of the PVC pipe:
  4. The joint must be tightened to prevent water leakage.
Drain Pipe Connection
Drain Pipe Connection

As a manufacturer, we can …

We can produce 28 different types of fan coil units, with a daily output of 2,000 units.

welcome to

About Yesncer

       Most of my long-term and stable customers are large-scale engineers and project builders. They customized the fan coil unit chilled water mold and developed the ducted fan coil unit control PCB.
       Our R&D team can fully meet your various needs, and we have the ability to undertake the production and R&D of large-scale engineering projects.

0 +

Countries

0 %

Service Guarantee

0 +

Engineer

Years 0 +

Production experience

After you order

Next are the following processes

 

Delivery Time

3-5 days for less than 2000 sets; 7-10 days for 2000-5000 sets;  15-20 days for more than 5000 sets.

 

Payment Method

EXW,FOB,CIF,DDP,T/T,L/C.

 

Shipping Method

By Sea , By Air , By Express Delivery, By Railway , By Land.

General Faq

Trust us, choose us, design equipment, complete the project

How to ensure product quality?

Support factory inspection. You can find a regular quality inspection agent in China and check the quality in the factory. I'll bear the cost.

Worried about not delivering/delaying delivery?

Can only pay me 10%-30% in advance, and then give me all the expenses when all the chilled water ducted fan coil units  are produced and delivered.

Ducted fan coil unit warranty for several years?

Ducted fan coil unit warranty for several years?

Choose me, what are my product advantages?

I am a professional manufacturer of ducted fan coil in China. Has its own laboratory and R&D team. Everyone is an experienced and professional technician. We can customize the fan coil unit that is more suitable for each customer according to his needs. And I am a manufacturer, different from the distributor, I can give you the ex-factory price of the products. My ducted fan coil unit is sold at a low price only because I am exploring the global market.

FCL Shipment Loading Site

My-Certificates

My Certificates

My-Successful-Customers

Construction Case

Certificate

Every project, we do care for our parter

Provide professional central air-conditioning terminals for every contractor to ensure your project is delivered on schedule

Copper tube thickness and diameter of chilled water fan coil unit surface cooler

Pure copper tube has higher heat exchange efficiency, long service life, and high compressive strength.

The water-collecting head is made of red copper material, and the overall thickness of the parts is increased.

Compared with other chilled water fan coil unit manufacturer, the weight of the water collecting head is about 100 grams, and the service life of the water collecting head is longer.

Please enter your email to let us contact you

We will contact you within 1 working day, please pay attention to the email with the suffix “@aircolder.com”

Yesncer Fan Coil Unit Manufacturer

Search

Sign up to our newsletter

Welcome Back

Everything is where you left it.

Which product are you interested in?

Fill out the form below to tell us what products and information you are interested in, or tell us about your project.

We will reply within 24 hours.

Registration

To reserve your ticket please fill out the registration form